Advertisement
Advertise Here
-
March 23, 2011
[an error occurred while processing this directive]
Forensic Chemistry: A new method could increase the number of explosives detected by airport screeners.
Trade: U.S. companies complain of market dumping by China.
Layoffs follow similar moves by Amgen, AstraZeneca.
Environment: Ban to halt export of hazardous waste to developing world.
Penrose (Parney) Albright will direct DOE national lab.
Toxic Exposure: Mercury isotopes in human hair illuminate dietary and industrial sources.
Cancer Biochemistry: Mass spectrometry follows the metabolism of very long fatty acids in cancer cells.
Proteomics researchers grapple with finding a certain protein in a veritable alphabet soup of others. Now scientists have devised a simple microfluidic method that can pull out specific proteins from a complex mixture (Anal. Chem., DOI: 10.1021/ac200073p).
Microfluidic characterization of proteins appeals to researchers because they can work with small amounts of their precious samples. But isolation of a protein from a sample "is always plaguing microfluidic analyses," explains bioengineer Greg Sommer at Sandia National Laboratories.
Researchers previously attempted to separate proteins by isoelectric focusing. Proteins flowed along in a solution with a pH gradient. When they hit the pH values at which they became neutrally charged, known as their pI values, they stopped moving. But because the method lacked a physical way to keep the isolated proteins in place, protein bands would bleed into each other.
Sommer’s team took a different tack: They downsized a membrane-based benchtop isoelectric focusing method. The researchers used polyacrylamide membranes with different pHs to separate the proteins.
When a protein mixture flowed down the microfluidic channel, the membranes trapped proteins based on their characteristic pI values. The separation took a few minutes; the benchtop method takes hours. Because the membranes kept the proteins separate, the investigators were able to capture clean samples for further characterization.
Using membranes with pH values between 5.3 and 6.5, the investigators could reproducibly separate model antibodies and enzymes dissolved in a simple buffer or within a bacterial cell lysate. Sommer says that they are now working on fine-tuning the pH values to improve the separation power of the method.
ACS is the leading employment source for recruiting scientific professionals. ACS Careers and C&EN Classifieds provide employers direct access to scientific talent both in print and online. Jobseekers | Employers
Join more than 161,000 professionals in the chemical sciences world-wide, as a member of the American Chemical Society.
» Join Now!